Key Features
-
| Frequency range 100 kHz - 3 GHz / 8.5GHz
-
| 125 dB wide dynamic range
-
| Various display formats
-
| Multiple calibration methods
-
| Standard interfaces including USB, LAN, GPIB, VGA
-
| Low noise level, good measurement performance
-
| Multi-window, multi-channel measurement display
Applications
-
| Measure communication products
-
| Passive multi-port device and balance device test
Technical Specifications
Specifications Model S3601A 3601B Frequency Range 100kHz - 3GHz 100kHz - 8.5GHz Frequency Resolution 1Hz Frequency Accuracy ±5×10-6 (23°C±3°C) ±5×10-6 (23°C±3°C) Output Power -45dBm - 10dBm -55dBm - 10dBm Max. Dynamic Range 125 dB 125 dB IF Bandwidth 1MHz - 5MHz Number of Built-In Ports 2 2 Measurement Point 1 - 16001 No. of Measurement Receiver 4 Reference Level Amplitude Setting Range: ±500dB; Resolution: 0.001dB Reference Phase Settings Range: ±500°; Resolution: 0.01° Measurement Fields Frequency domain and Time domain Display Format logarithmic amplitude, linear range, standing wave, phase, group delay, smith chart, polar diagram General Information
Dimension (W x H x D) 435×233×348 mm Weight 16 kg Power Supply 50 Hz 220 V AC / 60 Hz 110 V AC Interface N (F), 50Ω system impedance N (F), 75Ω system impedance (option 01) Operation Temp. 0 °C - +40 °C (32 °F - 104 °F) Storage Temp. -20 °C - +70 °C (-4 °F-158 °F) Relative Humidity <= 90 %rh Options of S3601A Vector Network Analyzer
Option No. Item Description S3601A-01 75Ω port impedance system \ S3601A-02 N-type testing cable (GORE-OSZKUZKU0240) Male - Male, 60cm S3601A-03 N-type testing cable (GORE-OSZKUZKU0240) Female - Male, 60cm S3601A-05 20205 N-type calibration kit DC - 3GHz S3601A-06 20204 N-type 75Ω calibration kit \ S3601A-07 Economical stable testing cable Saluki-N/J.SMA/J.197C-800, N-type to 3.5mm connector, dual male, 80cm
S3601A-08 Economical stable testing cable Saluki-N/J.N/K.197C-800, N-type connector,
female-male, 80cm
S3601A-09 Economical stable testing cable Saluki-N/J.N/J.197C-800, N-type connector, dual male, 80cm S3601A-10 75Ω testing cable 24-0800-51M1-51M1 S3601A-11 20402 Electronic calibration kit 300kHz-18GHz, N Type (female to male), 2 port S3601A-12 20403 Electronic calibration kit 10MHz-26.5GHz, 3.5mm (female to male), 2 port S3601A-13 20405 Electronic calibration kit 10MHz-20GHz, 3.5mm (female), 4 port S3601A-16 Aluminum carrying case \ S3601A-17 Front panel jumper Supports 4-port extension and receiver through test S3601A-18 2813A 4-port test equipemt Need option S3656A-17 S3601A-19 Cabinet Easy to build system Options of S3601B Vector Network Analyzer
Option No. Item Description S3601B-02 N-type testing cable (GORE-OSZKUZKU0240) Male - Male, 60cm S3601B-03 N-type testing cable (GORE-OSZKUZKU0240) Female - Male, 60cm S3601B-07 Economical stable phase testing cable Saluki-N/J.SMA/J.197C-800, N-type to 3.5mm
connector, dual male, 80cm
S3601B-08 Economical stable phase testing cable Saluki-N/J.N/K.197C-800, N-type connector,
female-male, 80cm
S3601B-09 Economical stable phase testing cable Saluki-N/J.N/J.197C-800, N-type connector, dual male, 80cm S3601B-11 20402 Electronic calibration kit 300kHz-18GHz, N Type (female to male), 2 port S3601B-12 20403 Electronic calibration kit 10MHz-26.5GHz, 3.5mm (female to male), 2 port S3601B-13 20405 Electronic calibration kit 10MHz-20GHz, 3.5mm (female), 4 port S3601B-16 Aluminum carrying case \ S3601B-18 2813A 4-port test equipemt Need option S3656B-29 S3601B-19 Cabinet Easy to build system S3601B-21 20201 N-type calibration kit DC - 9GHz S3601B-22 20202 3.5mm calibration kit DC - 9GHz S3601B-23 32111 waveguide calibration kit 1.72GHz - 2.61GHz S3601B-24 32112 waveguide calibration kit 2.6GHz - 3.95GHz S3601B-25 32113 waveguide calibration kit 3.94GHz - 6.0GHz S3601B-26 32114 waveguide calibration kit 4.64GHz - 7.05GHz S3601B-27 32115 waveguide calibration kit 5.88GHz - 8.17GHz S3601B-28 32116 waveguide calibration kit 7.0GHz - 10.0GHz S3601B-29 Front panel jumper Supports 4-port extension and receiver through test