AGILENT /VARIAN TV 81-M TURBO PUMP
AGILENT /VARIAN TV 81-M TURBO PUMP Agilent / Varian Turbo Pumps Vacuum Products Malaysia, Penang, Singapore, Indonesia Supplier, Suppliers, Supply, Supplies | Hexo Industries (M) Sdn Bhd
AGILENT / VARIAN TV 81-M TURBO PUMP  
(These models already Obsoleted or Discontinue. Pls email us at  sales@hexoind.com  for replacement turbo pump model)



 
 Order Information

 Part Number : 969-8901, 969-8902, 969-8903, 969-8904 


Part number Description
EX9698988 EXCHANGE TURBO-V 81-AG CONTROLLER BASE
EX9698989 EXCHANGE TURBO-V 81-AG CTRL RS 232/485
EX9698995 EXCHANGE V81 NAVIGATOR CONTROLLER 24V
EX9698996 EXCHANGE V81 NAVIGATOR CONTROL. 120/220V
EX9699538 EXCHANGE TURBO-V 81 PCB CONTROLLER 24VDC
9698988 TURBO-V81 AG 1/4 RACK CTRL 100-240V
9698989 CNT81-AG WITH RS232/485 OPTN
9698990 V81 AG 1/4 RACK CTRL 100-240V + PROFIBUS
9698995 TURBO-V81 NAVIGATOR CONTROLLER 24V
9698996 TURBO-V81 NAVIGATOR CONTROLLER 120/220V
9699538 TURBO-V81 24 PCB CONTROLLER
9698905 TURBO-V 81-T PUMP ISO 63
9698906 TURBO-V 81-T PUMP KF 40
9698907 TURBO-V 81-T PUMP CFF 4 1/2
9698908 Turbo-V 81-T Pump CFF 2.75 in
9699164 Controller Adapter Kit TV 70 - TV 81
9699801 Heater Band for Turbo-V70/V81, 220V
9699802 Heater Band for Turbo-V70/V81, 120V


ACCESSORIES AND SPARE PARTS
 
DESCRIPTION PART NUMBER
Inlet screen, DN 40 969-9309
Inlet screen, DN 63 969-9300
Heater band 220 V 969-9801
Heater band 120 V 969-9802
Metallic water cooling kit 969-9823
Plastic water cooling kit 969-9824
Air cooling kit (0.5 m cable) 969-9290
Air cooling kit extension cable (5 m) 969-9940
Pump extension cable 969-9942
Vibration damper DN 63 969-9375
Vibration damper CFF 4.5'' 969-9376
Mechanical pump DS 102 949-9315
Mechanical pump DS 42 949-9309
Dry scroll SH 100 SH01001 UNIV
Dry scroll SH 110 SH01101 UNIV
Rack controller 81-AG base 969-8988
Rack controller 81-AG RS232/485 969-8989
Rack controller 81-AG Profibus 969-8990
PCB 24 V 969-9538
Turbo-V 81-AG Navigator Controller 24 Vdc 969-8995
Turbo-V 81-AG Navigator Controller 100-240 Vac 969-8996
 

VENT VALVE MODEL SELECTION TABLE
CONTROL UNIT MODEL VENT VALVE PART NUMBER
Turbo-V 81-AG Navigator Controller (cable 0.7 m)
(any version)
N.O. 969-9844
Turbo-V 81-AG Rack Controller (cable 0.7 m)
(any version)
N.O. 969-9844
Controller TV70 Navigator (P/N 969-8970, 969-8971) 969-9834
Turbo-V 70 Rack controller (P/N 969-9405, 969-9505) 969-9843




 
 

TECHNICAL SPECIFICATION

Pumping speed With ISO 63 or CFF 4.5''
N2: 77 l/s
He: 65 l/s
H2: 50 l/s
With KF 40 NW or CFF 2.75''
N2: 50 l/s
He: 56 l/s
H2: 46 l/s
Compression ratio N2: 3 x 108
He: 8 x 104
H2: 7 x 103
Base pressure * (with recommended forepump) mechanical:
5 x 10-10 mbar (3.8 x 10-10 Torr) diaphragm:
5 x 10-9 mbar (3.8 x 10-9 Torr)
Inlet flange ISO 63                      KF 40 NW
CFF 4.5'' O.D.         CFF 2.75'' O.D.
Foreline flange KF16 NW
Rotational speed 1350 Hz (max)
Start-up time < 60 seconds
Cooling requirements Natural air convection Forced air or water optional
Recommended forepump mechanical: Varian DS 42 DS 102 dry pump: Varian SH 100
Operating position any
Coolant water flow: 10 l/h (0.05 GPM) temperature: + 15 °C to + 35 °C pressure: 2 to 4 bar (30 to 60 Psi)
Operating ambient temperature with natural air convec- tion +5 °C to +25 °C
Operating ambient temperature with forced air cooling or water +5 °C to +35 °C
Bakeout temperature 120° C at inlet flange max. (CF flange) 80° C at inlet flange max. (ISO flange)
Vibration level < 0.01 mm at inlet flange

(displacement)  
Noise level £ 45 dB (A) at 1 meter
Compliance with: UNI EN 292-1
UNI EN 292-2
EN-CENELEC 55011
IEC 1000-4-2 (ex 801-2)
IEC 1000-4-3 (ex 801-3)
IEC 1000-4-4 (ex 801-4)
EN 61010-1 (IEC 1010-1)
EN 1012-2
Storage temperature -20° C to +70° C
Input 60 Vac, three phase, 1350 Hz (max)
50 W max
Lubricant permanent lubrication
Installation category II
Pollution degree 2
Storage temperature - 20° C to + 70° C
Weight kg (lbs): ISO 63: 1.99 (4.39)
KF 40: 1.96 (4.32)
CFF 4.5'': 2.96 (6.53)
CFF 2.75'': 2.77 (6.11)
* (According to standard DIN 28 28, the base pressure is that measured in a ea -free test dome, 8 hours after the comp e- tion of test dome ba e-out, with a Turbopump fitted with a Con- F at f ange and using the recommended pre-vacuum pump)

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version