Power quality analyzer Class A PQM4000
PQM4000 (DIN 192×144) is a high-end power quality analyzer, able to monitor and record the major power quality parameters. It provides an accurate measurement, voltage characteristics are monitored according to Class A specification. It acts as event/fault recorder, capable to store a high number of voltage events and disturbances, frequency variations, inrush current, etc.
Additional PQ data can be recorded, such as Flicker, Unbalance, Harmonics (up to 63rd) and Interharmonics, Mains Signalling. Extra voltage and current measurement channels give the possibility to monitor Neutral Potential and Earth Leakage current.
PQM4000 is available for external standard CTs with 1 or 5A output or for current clamps.
PQM4000 includes different communication ports so the user can access it in different ways.
Auxiliary power voltage: 100…240 VAC 50/60 Hz / 65…250 VDC
Measurement inputs
Voltage inputs for direct connection: Phase-neutral (L-N): max 580 V RMS CAT III
Phase-phase (L-L): max 1000 V RMS CAT III
CT inputs: max 7 A RMS
Accuracy
Active energy: Class 0.5S, compliant to IEC/EN 62053-22
Reactive energy: Class 1, compliant to IEC/EN 62053-23
I/O Channels
Digital inputs: 4 optoisolated 24 VDC
Analog outputs: 4 optoisolated 4…20 mADC / max load 500 Ω
Digital outputs: 4 passive optoisolated 24 VDC / max 50 mA
Memory
System memory: 128 MB Flash, 256 MB RAM
Recording memory: 16 GB
Communication
Ethernet ports: 2 Auto MDIX RJ45 10/100 Base Ethernet
RS485 port: 1 optoisolated, 4800…115200 bps
GPS port: 1 SMA female connector
WIFI port: 1 SMA female connector
Protocols: HTTP, HTTPS, FTP, SFTP, NTP, NMEA, Modbus RTU/TCP, WPA
Environmental conditions
Installation and use code: PQI-A-FI1-H
Mechanical characteristics
Mounting: Panel mount 192×144 DIN size
Additional PQ data can be recorded, such as Flicker, Unbalance, Harmonics (up to 63rd) and Interharmonics, Mains Signalling. Extra voltage and current measurement channels give the possibility to monitor Neutral Potential and Earth Leakage current.
PQM4000 is available for external standard CTs with 1 or 5A output or for current clamps.
PQM4000 includes different communication ports so the user can access it in different ways.
TECHNICAL SPECIFICATIONS
Power supplyAuxiliary power voltage: 100…240 VAC 50/60 Hz / 65…250 VDC
Measurement inputs
Voltage inputs for direct connection: Phase-neutral (L-N): max 580 V RMS CAT III
Phase-phase (L-L): max 1000 V RMS CAT III
CT inputs: max 7 A RMS
Accuracy
Active energy: Class 0.5S, compliant to IEC/EN 62053-22
Reactive energy: Class 1, compliant to IEC/EN 62053-23
I/O Channels
Digital inputs: 4 optoisolated 24 VDC
Analog outputs: 4 optoisolated 4…20 mADC / max load 500 Ω
Digital outputs: 4 passive optoisolated 24 VDC / max 50 mA
Memory
System memory: 128 MB Flash, 256 MB RAM
Recording memory: 16 GB
Communication
Ethernet ports: 2 Auto MDIX RJ45 10/100 Base Ethernet
RS485 port: 1 optoisolated, 4800…115200 bps
GPS port: 1 SMA female connector
WIFI port: 1 SMA female connector
Protocols: HTTP, HTTPS, FTP, SFTP, NTP, NMEA, Modbus RTU/TCP, WPA
Environmental conditions
Installation and use code: PQI-A-FI1-H
Mechanical characteristics
Mounting: Panel mount 192×144 DIN size